Mentor MP is Control Techniques 5th generation DC drive and integrates the control platform from the world’s leading intelligent AC drive, Unidrive SP. This makes Mentor MP the most advanced DC drive available, giving optimum performance and flexible system interfacing capability.
There are large numbers of DC motors in service throughout the world in various applications, the majority of which are easily capable of providing ongoing service. Upgrading your DC drive allows you to maximise the motor performance, enhance system reliability and interface digitally with modern control equipment using Ethernet and Fieldbus networks. Downtime is minimised as only the drive needs to be replaced.
DC drive technology remains cost effective, efficient and is relatively simple to implement. For new applications, DC provides many advantages, especially for regenerative and high power applications.
Mentor MP has been engineered as an easy replacement for Mentor II. It has the same physical dimensions and connection layout. Software tools have been developed to easily migrate to the new platform.
Built in field controller as standard
Gives excellent field control for the majority of DC motors
Reduces the need for external components
The FXMP25 may be controlled digitally by using a standard RJ45 connection, allowing set-up by standard drive parameters
The FXMP25 can also function in standalone mode using its integrated keypad and display
The heatsink cooling fans are intelligently controlled and only run when required, thus increasing reliability and reducing maintenance
Eighteen different option modules allow customisation of the drive, including Fieldbus, Ethernet, I/O, extra feedback devices and motion controllers
The drive system designer is able to embed automation and motion control within the drive, eliminating communications delays that reduce performance
Communication modules including SM-CANopen, SM-DeviceNet, SM-EtherCAT, SM-Ethernet, SM-Interbus, SM-Profibus-DP, SM-Profinet
Keypads and storage including MP-Keypad, SM-Keypad and Smartcard
A range of I/O expansion modules
Encoder feedback modules
Quick and easy to set-up
Can be configured using optional removable keypads
Advanced autotune features help you get the best performance from your machine
PC software and Smartcard tools for rapid commissioning
Intelligent networked system with CTNet
Program inbuilt controller with SyPTLite
Develop tailored solutions for applications modules with SyPTPro
Option modules for all common Industrial Ethernet, Fieldbus networks
Easy integration with your existing motor, power supply, application equipment and communication networks has been ensured from the design stage
Mentor MP brings performance and possibilities to your application with minimum migration costs
Mentor MP has been designed so existing Mentor II customers can easily migrate to the new platform
All power terminal locations and mounting points have been retained
Mentor MP has a much smaller frame size than the 900 A Mentor II with paralleling options to offer high power density
CT Soft has a built in migration wizard to assist with the transfer of drive parameters and programs
Smaller cable requirements make connections within the cubical easier. Construction of a custom-made bus-bar is not required
Built in field controller as standard in every Mentor MP
Gives excellent field control for the majority of DC motors
Reduces the need for external components
An external motor field controller is recommended when:
The required field current is greater than that offered by the standard drive, up to 25 A. For example, older motors with low field voltages
The field is required to be forced down more quickly than is possible with a standard half controlled field bridge
Applications can be implemented with simple field current reversal, without armature reversal, if machine dynamics can still be met
Mentor MP is an ideal retro-fi t choice with features to ensure it can integrate easily with your existing motor, power supply, application equipment and communication networks. Mentor
MP brings new performance and new possibilities to your application with minimum projects costs.
Mentor MP has been designed so existing Mentor II customers can easily migrate to the new platform. All power terminal locations and mounting points have been retained and software
tools have been developed to assist transfer of drive parameters and programs. If you are planning to upgrade your DC system, whether it is a Mentor or other manufacturer’s drive, Mentor MP is the clear choice.
The new FXMP25 replaces our existing FXM5 option. It may be controlled digitally by the Mentor MP or Mentor II using a standard RJ45 connection, allowing set-up by standard drive
parameters. The FXMP25 has the same physical dimensions as the existing FXM5, but extends its current range to 25A. In standalone mode it is configured by its own keypad and display.
Northern Industrial can assist with all upgrade and retrofit enquiries, get in touch and we will be more than happy to specify the perfect drive for your requirements.
Les spécifications ci-dessous sont applicables à ce produit
Manufacturer | Control Techniques |
---|---|
Supply Voltage | 380...480V AC |
Range | Mentor MP |
Range type | DC Drive |
Depth | 251 |
Width | 293 |
Height | 444 |
Notes | 3 of the 6 digital inputs can be configured as outputs |
Logic | Positive Negative |
Isolation | Isolated |
Analogue/Digital | Digital |
Mouting Style | Panel |
Field Supply | Integral Field weakener |
---|---|
Relay outputs | 2 |
Input Phase | 3 |
Digital Outputs | 3 |
Digital Inputs | 6 |
Analogue Outputs | 2 |
Analogue Inputs | 3 |
Keypad Included | Yes |
Regenerative | Not regenerative |
Amp | 105 |
kW | 38 |