The Control Techniques UD51 is a second encoder feedback module for the Unidrive classic series of AC drives.The UD51 is used where the reference signal and motor feedback signals are both EAI485 quadrature format.  The module allows the Unidrive to receive feedback from a second encoder or change the encoder input to a reference input and can also be used with frequency oand direction signals. Freeze input is also available.

 

UD51 Technical Specifications
Pin NumberNameFunction 
40ENCAP A to F EIA485 input
41 ENCAN  A to F EIA485 input
42 OV  
43 ENCBP B to D EIA485 input
44 ENCBN B to D EIA485 input
45 OV  
46 ENCZPZ EIA485 input
47 ENCZN Z EIA485 input 
48 OV  
49 FENCAP F to A EIA485 input
50 FENCAN F to A EIA485 input 
51OV  
52 DENCBP D to B EIA485 input
53 DENCN D to B EIA485 input
54 FRZP Freeze EIA485 input to Z EIA485 output
55FRZNFreeze EIA485 input to Z EIA485 output

 

UD51 Encoder Inputs

 

The A, B amd Z inputs may be configured for frequency and direction or quadrature format. The position is latched on the rising edge of Z when the direction is forward and on the failing edge when the direction is reversed. Termination resistorss can be selected by a parameter and do not have series capacitors. Input filters and over voltage protection are fitted to all three inputs.

 

User Outputs

On the Control Techniques UD51 the F and D outputs, enable the user to monitor the frequency and direction of the encoder/drive signal. The F and D outputs are derived from either the main encoder inputs or the encoder inputs to this module. The resolution can be reduced by any powerof 2 and the formatof the output can be either frequency and direction or quadrant. Delay encoder (main or 2nd) input to output.

 

User Input/Output

The signal can be programmed as a freeze input or a Z output by setting the appropriate parameter. If the Z output is chose the output is beffered version of the Z input of the main encoder. If used a freeze input when a positive transition is deteced the position of both the main encoder and the 2nd encoder inputs are stored. There may be a small delay in latching the position but bohth will be latched together. Output and input modes comply with EIA485. 

 

PDFs

Les spécifications

Les spécifications ci-dessous sont applicables à ce produit

ManufacturerControl Techniques
ApplicationHigh Performance / HVAC Fan & Pump
Range typeInterface Module
RangeUnidrive
PDFs

Vous recherchez plus d'informations sur ce produit?

Voici quelques fichiers PDF, vous pouvez télécharger

Stopping downtime for over 40 years

En savoir plus sur nous

Northern Industrial We’ve come a long way since our small workshop in the 90s.
Northern Industrial Microsoft did a story on us after we were the first business in the whole of the UK to install Windows 2000 server.
Northern Industrial Back in the early 2000s we had a small group of engineers compared to over 40 today.
Northern Industrial We’re continuously developing our test facilities including the use of robots.
Northern Industrial Our current building is home to thousands of automation parts in Lancashire, England.
Northern Industrial Celebrating our 40th birthday in 2018 with John (centre) who started Northern Industrial back in 1978!