The Control Techniques UD53 is a Resolver Feedback Module designed to accept sinusoidal motor position feedback signals from a motor shaft encoder. The module offers simulated encoder (EIA485 quadrature or frequency and direction) output and easy drive positioning feedback in rugged and demanding environments. The UD53 is installed below the keypad of the Control Techniques UniDrive Classic. 

Control Techniques UD53 Specifications
Resolver Excitation Output
Output Wave Form6K Hz 6 Vrms sine wave
ProtectionOver current and series fernite beads
Absolute maximum applied DC voltage (REFH)+24V - 4V
Absolute maximum applied current (REFH, OVREF) 
Resolver Inputs
ProtectionSeries resistors and clamp diodes
Absolute maximum applied DC Voltage

(SINRL, COSL) +4V

(SINH, COSH) +12V

 

Resolver Resolution

The resolver resolution is determined by the maximum required speed as set up in parameters of the drive. The maximum speed can be changed when the drive is enabled but only if the resolution of the resolver does not also require changing.

Maximum Motor SpeedResolver ResolutionSimulated Encoder Output PPR in Quadrature Mode
0-3000 rpm14 bit4096
3001-12000 rpm12 bit1024
>12000 rpm10 bit256

 

Encoder Simulation Output

The encoder simulation output is derived from the resolver through a digital conversion IC within the Control Techniques UD53 module. The maximum number of pulses per revolution is equal to the resolution of the resolver divided by four. Changing the maximum speedof the motor so that the resolution changes will cause loss of position. 

The encoder resolution can be reduced further by using divide parameters; changing this parameter will also cause a loss of position. The zero pulse position can only be change by rotating the resolver relative to the shaft. The outputs are to the EIA-485 specification/

 

 

PDFs

Les spécifications

Les spécifications ci-dessous sont applicables à ce produit

ManufacturerControl Techniques
ApplicationHigh Performance / HVAC Fan & Pump
Range typeInterface Module
RangeUnidrive
PDFs

Vous recherchez plus d'informations sur ce produit?

Voici quelques fichiers PDF, vous pouvez télécharger

Stopping downtime for over 40 years

En savoir plus sur nous

Northern Industrial We’ve come a long way since our small workshop in the 90s.
Northern Industrial Microsoft did a story on us after we were the first business in the whole of the UK to install Windows 2000 server.
Northern Industrial Back in the early 2000s we had a small group of engineers compared to over 40 today.
Northern Industrial We’re continuously developing our test facilities including the use of robots.
Northern Industrial Our current building is home to thousands of automation parts in Lancashire, England.
Northern Industrial Celebrating our 40th birthday in 2018 with John (centre) who started Northern Industrial back in 1978!