Simatic S7-400H, CPU 414-4H Processor Module , 4 Interfaces and 768 KB Memory
Description

O tomto produkte

Tu je všetko, čo potrebujete vedieť

Part of the Simatic S7-400 programmable controller range, the 6ES7414-4HJ00-0AB0 is a CPU 414H Processor Module which features 4 Interface ports ( 1 MPI/DP, 1 DP and 2 for sync modules) as well as 768 KB memory (384 KB DATA/384 KB code). Sadly the module was made obsolete in 2010 and is no longer available through the main Siemens catalogue.  Northern Industrial offer a repair service on these units as well as high quality refurbished units. 

Technical Specifications
Supply voltage
24 V DCYes
Input current
from backplane bus 5 V DC, typ.1.8 A
from backplane bus 5 V DC, max.2 A
from backplane bus 24 V DC, max.300 mA; Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface
Power loss
Power loss, typ.10 W
Memory
Work memory
integrated768 kbyte; 384 KB for program; 384 KB for data
expandableNo
Load memory
expandable FEPROMYes; with Memory Card (FEPROM)
expandable FEPROM, max.64 Mbyte
integrated RAM, max.256 kbyte
expandable RAMYes; with Memory Card (RAM)
expandable RAM, max.64 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
Battery
Backup battery
Backup current, typ.75 µA
Backup current, max.860 µA
Feeding of external backup voltage to CPU5 to 15 VDC
CPU processing times
for bit operations, typ.0.1 µs
for word operations, typ.0.1 µs
for fixed point arithmetic, typ.0.1 µs
for floating point arithmetic, typ.0.6 µs
CPU-blocks
DB
Number, max.4095; DB 0 reserved
Size, max.64 kbyte
FB
Number, max.2048
Size, max.64 kbyte
FC
Number, max.2048
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Nesting depth
per priority class24
Counters, timers and their retentivity
S7 counter
Number256
Retentivity
adjustableYes
lower limit0
upper limit255
presetZ 0 to Z 7
Counting range
lower limit1
upper limit999
IEC counter
presentYes
TypeSFB
S7 times
Number256
Time range
lower limit10 ms
upper limit9990 s
IEC timer
presentYes
TypeSFB
Data areas and their retentivity
Flag
Number, max.8 kbyte
Retentivity availableYes; from MB 0 to MB 8191
Retentivity presetMB 0 to MB 15
Data blocks
Number, max.4096; DB 0 reserved
Size, max.64 kbyte
Address area
I/O address area
Inputs8 kbyte
Outputs8 kbyte
of which distributed
MPI/DP interface, inputs2 kbyte
MPI/DP interface, outputs2 kbyte
DP interface, inputs6 kbyte
DP interface, outputs6 kbyte
Process image
Inputs, adjustable8 kbyte; adjustable at the expense of the code area of the RAM
Outputs, adjustable8 kbyte; adjustable at the expense of the code area of the RAM
Inputs, default1024 byte
Outputs, default1024 byte
Subprocess images
Number of subprocess images, max.8
Digital channels
Inputs65536
Outputs65536
Inputs, of which central65536
Outputs, of which central65536
Analog channels
Inputs4096
Outputs4096
Inputs, of which central4096
Outputs, of which central4096
Hardware configuration
Expansion devices, max.21
MulticomputingNo
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.6; IM 463-2
Number of DP masters
integrated2
via IM 4670
via CP10
Mixed mode IM + CP permittedNo; IM 467 cannot be used jointly with CP 443-5 Ext.
via interface module0
Number of operable FMs and CPs (recommended)
FM32; Limited by number of slots and number of connections
CP, point-to-point32; Limited by number of slots and number of connections
CP, LAN32; Limited by number of slots and number of connections
Slots
required slots2
Time of day
Clock
Hardware clock (real-time clock)Yes
battery-backed and synchronizableYes
Operating hours counter
Number8
Clock synchronization
supportedYes
1. Interface
isolatedYes
Functionality
MPIYes; Default setting
DP masterYes
DP slaveNo
MPI
Number of connections32
Transmission rate, max.12 Mbit/s
Services
PG/OP communicationYes
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientYes
S7 communication, as serverYes
DP master
Number of connections, max.32; of which 1 reserved for PG, 1 for OP
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32; Number of slots, max. 512
Services
PG/OP communicationYes
Global data communicationNo
S7 basic communicationNo
S7 communicationNo
Equidistance mode supportNo
SYNC/FREEZENo
Activation/deactivation of DP slavesYes
Direct data exchange (slave-to-slave communication)No
Address area
Inputs, max.2 kbyte
Outputs, max.2 kbyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
Slots, max.244
per slot, max.128 byte
2. Interface
isolatedYes
Functionality
DP masterYes; Default setting
DP slaveNo
Point-to-point connectionNo
DP master
Number of connections, max.32
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.96
Services
PG/OP communicationYes
Global data communicationNo
S7 basic communicationNo
S7 communicationNo
Equidistance mode supportNo
SYNC/FREEZENo
Activation/deactivation of DP slavesNo
Direct data exchange (slave-to-slave communication)No
Address area
Address area, max.8 kbyte
Inputs, max.8 kbyte
Outputs, max.8 kbyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
Communication functions
PG/OP communicationYes
Global data communication
supportedNo
S7 basic communication
supportedNo
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 kbyte
S5 compatible communication
supportedYes; via CP and loadable FC
User data per job, max.8 kbyte
Standard communication (FMS)
supportedYes; Via CP and loadable FB
User data per job, max.Dependent on CP
Number of connections
overall32
usable for PG communication 
reserved for PG communication1
adjustable for PG communication, max.0
usable for OP communication 
reserved for OP communication1
adjustable for OP communication, max.0
usable for S7 basic communication 
reserved for S7 basic communication0
adjustable for S7 basic communication, max.0
usable for routing 
reserved for routing0
adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.16
Test commissioning functions
Diagnostic buffer
presentYes
Number of entries, max.3200
adjustableYes
preset120
Configuration
Configuration software
STEP 7Yes; V5.0 SP2
Programming
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.1070 g
StatusJul 7, 2014
PDFs

špecifikácia

Uvedené špecifikácie sa vzťahujú k tomuto výrobku

ManufacturerSiemens
Alternative Partnumber6ES7 414-4HJ00-0AB0
Range typeProcessor Module
RangeSimatic S7-400
PDFs

Hľadá pre viac informácií o tomto produkte?

Tu sú niektoré súbory vo formáte PDF si môžete stiahnuť

Stopping downtime for over 40 years

Viac informácií o nás

Northern Industrial We’ve come a long way since our small workshop in the 90s.
Northern Industrial Microsoft did a story on us after we were the first business in the whole of the UK to install Windows 2000 server.
Northern Industrial Back in the early 2000s we had a small group of engineers compared to over 40 today.
Northern Industrial We’re continuously developing our test facilities including the use of robots.
Northern Industrial Our current building is home to thousands of automation parts in Lancashire, England.
Northern Industrial Celebrating our 40th birthday in 2018 with John (centre) who started Northern Industrial back in 1978!