Loading...

TWDLCAA24DRF
Telemecanique Twido extendable PLC base - 100..240 VAC supply - 14 I 24 V DC - 10 relay outputs

For more information on how your data is processed and stored please read our privacy policy.

2 year warranty 2 year warranty*

Worldwide delivery Worldwide delivery

Returns accepted Returns accepted

*Manufacturer's warranty does not apply

Twido extendable PLC base - 100..240 VAC supply - 14 I 24 V DC - 10 relay outputs
Description

About this product

Here is all you need to know

Range of product

Twido

Product or component type

Compact base controller

Discrete I/O number

24

Discrete input number

14

Discrete input voltage

24 V

Discrete input voltage type

DC

Discrete output number

10 for relay

Number of I/O expansion module

4

[Us] rated supply voltage

100...240 V AC

Use of slot

Memory cartridge or realtime clock cartridge

Data backed up

Internal RAM (lithium) 30 days , charging time = 10 hrs , battery life = 10 yr

Integrated connection type

Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII (RS485) half duplex , 38,4 kbit/s 
Power supply 
Serial link interface adaptor (RS232C/RS485)

Complementary function

PID 
Event processing

Discrete input logic

Sink or source

Input voltage limits

20.4...28.8 V

Discrete input current

7 mA for I0.2 to I0.13 
11 mA for I0.0 to I0.1

Input impedance

2100 Ohm for I0.0 to I0.1 
3400 Ohm for I0.2 to I0.13

Filter time

35 µs + programmed filter time for I0.0 to I0.5 at state 1 
40 µs + programmed filter time for I0.6 to I0.13 at state 1 
45 µs + programmed filter time for I0.0 to I0.5 at state 0 
150 µs + programmed filter time for I0.6 to I0.13 at state 0

Insulation between channel and internal logic

1500 Vrms for 1 minute

Insulation resistance between channel

None

Minimum load

0.1 mA

Contact resistance

≤ 30000 µOhm

Load current

2 A at 240 V AC resistive load, operating rate = 30 cyc/mn for relay outputs 
2 A at 30 V DC resistive load, operating rate = 30 cyc/mn for relay outputs 
2 A at 240 V AC inductive load, operating rate = 30 cyc/mn for relay outputs 
2 A at 30 V DC inductive load, operating rate = 30 cyc/mn for relay outputs

Mechanical durability

≥ 20000000 cycles for relay outputs

Electrical durability

≥ 100000 cycles for relay outputs

Current consumption

5 mA at 5 V DC at state 0 
36 mA at 5 V DC at state 1 
55 mA at 24 V DC at state 1

I/O connection

Non-removable screw terminal block

Input/output number

≤ 120 with spring terminal block with I/O expansion module 
≤ 152 with HE-10 connector with I/O expansion module 
≤ 88 with removable screw terminal block with I/O expansion module

Network frequency

50/60 Hz

Supply voltage limits

85...264 V

Network frequency limits

47...63 Hz

Power supply output current

0.25 A for 24 V DC sensors

Power supply input current

450 mA

Inrush current

≤ 40 A

Protection type

Power protection with internal fuse

Power consumption in VA

33 VA at 100 V 
40 VA at 264 V

Insulation resistance

> 10 MOhm at 500 V, between supply and earth terminals 
> 10 MOhm at 500 V, between I/O and earth terminals

Program memory

3000 instructions

Exact time for 1 K instruction

1 ms

System overhead

0.5 ms

Memory description

Internal RAM , 256 internal bits, no floating, no trigonometrical 
Internal RAM , 3000 internal words, no floating, no trigonometrical 
Internal RAM , 128 timers, no floating, no trigonometrical 
Internal RAM , 128 counters, no floating, no trigonometrical 
Internal RAM , double words, no floating, no trigonometrical

Free slots

1

Realtime clock

Without

Counting input number

1 channel(s) at 20000 Hz 32 bits 
3 channel(s) at 5000 Hz 16 bits

Analogue adjustment points

1 point adjustable from 0...1023 
1 point adjustable from 0 to 511 points

Marking

CE

Status LED

1 LED green for PWR 
1 LED green for RUN 
1 LED red for module error (ERR) 
1 LED for user pilot light (STAT) 
1 LED per channel green for I/O status

Product weight

0.305 kg

PDFs

The Specs

The below specs apply to this product

ManufacturerTelemecanique
Range typeBase Unit Rack
RangeTwido
EAN3595862044226
PDFs

Looking for more details on this product?

Here are some PDFs you can download

Stopping downtime for over 40 years

Learn more about us

Northern Industrial We’ve come a long way since our small workshop in the 90s.
Northern Industrial Microsoft did a story on us after we were the first business in the whole of the UK to install Windows 2000 server.
Northern Industrial Back in the early 2000s we had a small group of engineers compared to over 40 today.
Northern Industrial We’re continuously developing our test facilities including the use of robots.
Northern Industrial Our current building is home to thousands of automation parts in Lancashire, England.
Northern Industrial Celebrating our 40th birthday in 2018 with John (centre) who started Northern Industrial back in 1978!