The Siemens 6ES5308-3UC21 links the PROFIBUS-DP to the CPUs in the Simatic S5-115U, S5-135U and S5-155U programmable controllers. The module is frequently referred to as the IM 308-C in the Siemens literature and provides:
The following memory cards can be used with the IM 308-C:
Memory Size | Voltage | Order No. | Available |
256 Kbytes | 5V | 6ES5 374-1KH21 | yes |
1 Mbytes | 5V | 6ES5 374-1KK21 | yes |
256 Kbytes | 12V | 6ES5 374-1FH21 | no |
512 Kbytes | 12V | 6ES5 374-1FJ21 | no |
Please note that the refubished IM 308-C is not supplied with a 5V memory card.
If you try to program a 12 V memory card in a the 6ES5308-3UC21 with product version 1 and higher, the CPU and the IM 308-C will enter STOP mode. The "IF" LED will light up on the IM 308-C.
Designation | Function |
Backplane connectors X1 and X2 | Blackplane connector X1 and X2 enable communication between the IM308-C and the CPU via the S5 I/O bus. |
Memory card | All important configuration data for the IM308-C and bus layout is stored on the memory card. |
Mode Selector Switch (IM308-C as DP-Master) | RN (RUN): normal operation IM308-C read the inputs ofthe slave and sets the output ST (STOP): IM308-C does not exchange data with the slaves, it may, however, receive the token (send authorization) from another master on the bus and pass on the token. OFFL IM308-C does not exchange data with the slave and cannot receive the token (send authorization) from another master on the bus) |
Mode Selector Switch (IM308-C as DP-Slave) | RN (RUN): normal operation; IM 308-C is DP slave and exchange data with the DP master ST (STOP) or OFF: IM308-C is DP slave and does not exchange data with the DP master. No exchange of data between the IM308-C/DP slave and the slave CPU. Depending on parameterization with COM Profibus QVZ or PEU is reported to the master CPU. Bit ), station status 1, is set. |
LEDs | The meanings of the LEDs are shown in table 3-2 and 3.3 |
Profibus-DP | The bus connectors of the field bus connect to the IM308-C via the Profibus-DP |
Jumper X10 | Profibus-DP grounded or not grounded |
Jumper X9 | PEU signal switched (power fail in expansion unit) |
The below specs apply to this product
Manufacturer | Siemens |
---|---|
Alternative Partnumber | 6ES5 308-3UC21 |
Range type | Interface Module |
Range | Simatic S5 |
---|---|
EAN | 4025515066439 |