Twido Compact PLC base controller with 100-240VAC supply, 24 inputs (24VDC) and 16 output
Description

About this product

Here is all you need to know

Part of the Twido range of compact PLC base controllers, the TWDLCAE40DRF provides 24 discrete inputs at 24V, 14 relay outputs and 2 transistor outputs. The unit is powered from a 100..240VAC 3 phase supply. 

Range of product

Twido

Product or component type

Compact base controller

Discrete I/O number

40

Discrete input number

24

Discrete input voltage

24 V

Discrete input voltage type

DC

Discrete output number

2 for transistor 
14 for relay

Number of I/O expansion module

7

[Us] rated supply voltage

100...240 V AC

Use of slot

Memory cartridge

Data backed up

Internal RAM (external battery TSXPLP01) 3 years

Integrated connection type

Ethernet TCP/IP RJ45, , 10/100 Mbit/s , 1 twisted pair transparent ready class A10 
Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII (RS485) half duplex , 38,4 kbit/s 
Power supply 
Serial link interface adaptor (RS232C/RS485)

Complementary function

PID 
Event processing

 

Complementary Information

 

Concept

Transparent Ready

Discrete input logic

Sink or source

Input voltage limits

20.4...26.4 V

Discrete input current

7 mA for I0.2 to I0.5 
7 mA for I0.8 to I0.23 
11 mA for I0.0 to I0.1 
11 mA for I0.6 to I0.7

Input impedance

2100 Ohm for I0.0 to I0.1 
2100 Ohm for I0.6 to I0.7 
3400 Ohm for I0.2 to I0.5 
3400 Ohm for I0.8 to I0.23

Filter time

35 µs + programmed filter time for I0.0 to I0.5 at state 1 
40 µs + programmed filter time for I0.0 to I0.5 at state 0 
40 µs + programmed filter time for I0.6 to I0.23 at state 1 
150 µs + programmed filter time for I0.6 to I0.23 at state 0

Insulation between channel and internal logic

1500 Vrms for 1 minute

Insulation resistance between channel

None

Minimum load

0.1 mA

Contact resistance

≤ 30000 µOhm

Load current

2 A at 240 V AC resistive load, operating rate = 30 cyc/mn for relay outputs 
2 A at 30 V DC resistive load, operating rate = 30 cyc/mn for relay outputs 
2 A at 240 V AC inductive load, operating rate = 30 cyc/mn for relay outputs 
2 A at 30 V DC inductive load, operating rate = 30 cyc/mn for relay outputs

Mechanical durability

≥ 20000000 cycles for relay outputs

Electrical durability

≥ 100000 cycles for relay outputs

Current consumption

5 mA at 24 V DC at state 0 
90 mA at 5 V DC at state 1 
128 mA at 24 V DC at state 1 
128 mA at 24 V DC state 1 + input ON 
170 mA at 5 V DC at state 0 
240 mA at 5 V DC state 1 + input ON

I/O connection

Non-removable screw terminal block

Input/output number

≤ 152 with removable screw terminal block with I/O expansion module 
≤ 208 with spring terminal block with I/O expansion module 
≤ 264 with HE-10 connector with I/O expansion module

Network frequency

50/60 Hz

Supply voltage limits

85...264 V

Network frequency limits

47...63 Hz

Power supply output current

0.4 A for 24 V DC sensors

Power supply input current

790 mA

Inrush current

≤ 35 A

Protection type

Power protection with internal fuse

Power consumption in VA

65 VA at 100 V 
77 VA at 264 V

Insulation resistance

> 10 MOhm at 500 V, between supply and earth terminals 
> 10 MOhm at 500 V, between I/O and earth terminals

Program memory

3000 instructions

Exact time for 1 K instruction

1 ms

System overhead

0.5 ms

Memory description

Internal RAM , 256 internal bits, no floating, no trigonometrical 
Internal RAM , 3000 internal words, no floating, no trigonometrical 
Internal RAM , 128 timers, no floating, no trigonometrical 
Internal RAM , 128 counters, no floating, no trigonometrical 
Internal RAM , double words, no floating, no trigonometrical 
Internal RAM , floating, trigonometrical

Free slots

1

Realtime clock

With , drift: <= 30 s/month , operating time: 30 days

Port Ethernet

10BASE-T/100BASE-TX

Communication service

BOOTP client Ethernet TCP/IP 
Modbus messaging Ethernet TCP/IP

Positioning functions

PWM/PLS 2 channel(s) at 7 kHz

Counting input number

2 channel(s) at 20000 Hz 32 bits 
4 channel(s) at 5000 Hz 16 bits

Analogue adjustment points

1 point adjustable from 0...1023 
1 point adjustable from 0 to 511 points

Marking

CE

Status LED

1 LED green for PWR 
1 LED green for RUN 
1 LED red for module error (ERR) 
1 LED for user pilot light (STAT) 
1 LED for Ethernet status (LAN ST) 
1 LED for 10 or 100 Mbit/s rate (LACT) 
1 LED per channel green for I/O status

Product weight

0.525 kg

Enviromental

Immunity to microbreaks

10 ms

Dielectric strength

1500 V for 1 minute, between supply and earth terminals 
1500 V for 1 minute, between I/O and earth terminals

Product certifications

CSA 
UL

Ambient air temperature for operation

0...55 °C

Ambient air temperature for storage

-25...70 °C

Relative humidity

30...95 % without condensation

IP degree of protection

IP20

Operating altitude

0...2000 m

Storage altitude

0...3000 m

Vibration resistance

0.075 mm , 10...57 Hz mounting on: 35 mm symmetrical DIN rail 
1 gn , 57...150 Hz mounting on: 35 mm symmetrical DIN rail 
1.6 mm , 2...25 Hz mounting on: plate or panel with fixing kit 
4 gn , 25...100 Hz mounting on: plate or panel with fixing kit

Shock resistance

15 gn for 11 ms

RoHS EUR conformity date

0932

RoHS EUR status

Compliant

PDFs

The Specs

The below specs apply to this product

ManufacturerTelemecanique
Range typeBase Unit Rack
RangeTwido
PDFs

Looking for more details on this product?

Here are some PDFs you can download

PDF twdlcae40drf datasheet

Stopping downtime for over 40 years

Learn more about us

Northern Industrial We’ve come a long way since our small workshop in the 90s.
Northern Industrial Microsoft did a story on us after we were the first business in the whole of the UK to install Windows 2000 server.
Northern Industrial Back in the early 2000s we had a small group of engineers compared to over 40 today.
Northern Industrial We’re continuously developing our test facilities including the use of robots.
Northern Industrial Our current building is home to thousands of automation parts in Lancashire, England.
Northern Industrial Celebrating our 40th birthday in 2018 with John (centre) who started Northern Industrial back in 1978!